Cat6 vs. Cat6A vs. Cat8: Which Cable Does an Office Need?
From existing Cat5e in the walls to Cat8 in the server room: what each category is actually for, and what to specify in a new office.
Choosing a cable category is a design decision, not a brand name on a box. The category has to match the job: a desk, a Wi-Fi access point, a camera, or a short link in the server room. C13 installs Cat5e through Cat8 and fiber; we are not limited to Cat6 and Cat6A. This guide is the decision version of the table on our structured cabling page.
Category comparison
| Category | Max speed | Bandwidth | Max distance | Best for |
|---|---|---|---|---|
| Cat5e | 1 Gb (up to 2.5 Gb on a good link) | 100 MHz | 100 m | Existing wiring in older buildings; still fine for gigabit when it tests good |
| Cat6 | 1 Gb at 100 m; 10 Gb only on short runs | 250 MHz | 100 m (about 37–55 m for 10 Gb) | Desks, phones and printers when 10 Gb at full distance is not required |
| Cat6A | 10 Gb | 500 MHz | 100 m | Most new offices, Wi-Fi access points and long-life buildings |
| Cat7 / Cat7A | 10 Gb | 600 MHz / 1 GHz | 100 m | ISO/IEC systems (mostly Europe). Not a TIA category; true links use GG45 or TERA, not RJ45 |
| Cat8 | 25 / 40 Gb | 2,000 MHz | 30 m | Short, shielded data-center and server-room links — not office horizontal cabling |
Speeds and distances follow ANSI/TIA and IEEE application limits (and ISO/IEC for Cat7/7A). A link is only as good as its lowest-rated part, so the cable, jacks, panels and patch cords all need to match. Sources are listed at the bottom of this page and in the page source.
What to use where
- New offices, Wi-Fi and cameras: Cat6A is the all-around recommendation. It supports 10 Gb Ethernet over the full 100 m channel and handles heat in larger PoE bundles better than Cat6, which matters for Wi-Fi 6/6E/7 access points and many cameras. See also PoE for phones, cameras and Wi-Fi.
- Desks, phones and printers: Cat6 is still a solid, lower-cost choice when you do not need 10 Gb at full distance. Gigabit (and often 2.5 Gb on a good link) is plenty for a typical desk phone and computer.
- Existing Cat5e: Do not rip it out automatically. Cat5e is still a recognized TIA category and supports gigabit (and often 2.5 Gb) to 100 m when the installed link tests good. We test first and replace only what fails or no longer meets the need.
- Server rooms and short high-speed links: Cat8 is for shielded 25 or 40 Gb Ethernet up to 30 m (typically 24 m of cable plus short patch cords, with at most two connectors). It is not a substitute for everyday office horizontal cabling.
- Between floors, closets or buildings: That is often fiber, not a longer copper run.
Names that are not official categories
“Cat6A+” and “Cat6e” are marketing names, not official TIA or ISO categories. If you need 10 Gb to 100 m, specify true Cat6A. Cat7 and Cat7A are ISO/IEC standards (Class F and FA), not TIA standards, which is what most U.S. commercial work is certified to. True Cat7/7A uses specialized GG45 or TERA connectors, not the familiar RJ45 jack, so many “Cat7” cables sold with RJ45 plugs cannot be certified as a Cat7 channel. We will steer you to a standard we can test and document.
Other details that affect the result
- The whole channel matters. A Cat6A cable into a Cat5e jack or a cheap Cat5e patch cord is not a Cat6A link.
- Shielded vs. unshielded. Most office horizontal runs are unshielded (UTP) Cat6 or Cat6A. Cat8 is a shielded system and needs to be bonded correctly. Shielding is not a shortcut around poor installation.
- Plenum (CMP) vs. other jackets. The building and the space — for example a drop ceiling used as a return-air plenum — determine the jacket. We check that before we quote.
- Pathway size. Cat6A is thicker than Cat6. Closets, conduits and furniture ports need to be planned for that.
- Testing. Every run should be terminated, labeled and tested. Certification with a permanent-link tester is recommended for new installs and data centers.
Questions we hear a lot
Is Cat8 better for a regular office?
No. Cat8 is a short, shielded 25/40 Gb system with a 30 m limit. For desks, phones, cameras and access points, Cat6 or Cat6A is the right family. Use Cat8 in the server room when the link actually needs 25 or 40 Gb.
Should we replace all of our Cat5e?
Not automatically. If the installed links test good and gigabit (or 2.5 Gb) is enough, Cat5e can stay. We test first and replace only what fails or no longer meets the need.
What about Cat6A+ or Cat6e?
Those are marketing names, not official TIA or ISO categories. For 10 Gb to 100 m, specify true Cat6A.
Related guides
Related services: Structured cabling · Service areas
Need a hand from a local technician?
C13 serves Phoenix-metro businesses only, so when a phone call or remote change won't fix it, a C13 technician can come to your office. Commercial clients only.
Requests sent outside business hours (Monday–Friday, 8:00 AM–5:00 PM Arizona time, closed on holidays) are handled as after-hours work and billed at 1.5x our standard hourly rate; holidays and emergencies are billed at 2x. We respond within 2 to 4 hours after your email is read. For an emergency, email [email protected] with EMERGENCY in the subject line, or call (480) 397-2627.